20100919 09.30 -------------- Number of channels with pedestal = 0 rms = 0 for different times and RCUs. date time RCU0 RCU1 RCU2 run number ------------------------------------- 13/9 18.33 0 1 3 - 14/9 9.25 0 1 3 - 14/9 10.29 0 1 4 - 14/9 13.11 0 1 4 17188 readout errors at 16.00 was the system powered on and a higher temperature than normal observered power/currents adjusted on power supply 14/9 16.36 0 3 5 - 14/9 18.00 4 12 8 17198 14/9 19.10 1 3 5 17215 15/9 10.56 3 7 12 17234 15/9 12.05 3 7 13 17245 15/9 19.25 7 4 17 17262 16/9 10.08 9 11 28 17272 16/9 11.25 9 10 27 17283 GEM trip - repair 18/9 10.22 9 12 31 18/9 12.13 9 12 32 17298 18/9 16.16 9 13 28 17324 readout errors - adjust power + power off/on at around 15.30 did the temperature start to rise with 2.5 degrees on a FEC card. Most likely it was drawing more current. Fell again after adjust and power cycle 18/9 18.52 9 15 41 17340 18/9 21.14 9 14 37 17359 From this can I not conclude any reason for it, but it is clear that the number of channels with problems are increasing. Seems to be in steps. Channels with pedestal = 0 and rms = 0 for run 17385 RCU 0 2518 2519 2814 2843 2995 3448 3766 3767 3956 RCU 1 72 73 2199 2268 2626 2726 3191 3196 3197 3198 3199 3214 3382 3389 RCU 2 34 58 59 186 290 291 313 2074 2092 2107 2108 2109 2114 2132 2133 2147 2177 2178 2223 2239 2278 2339 2344 2349 2350 2393 2395 2446 2450 2453 2465 2469 2500 2501 2906 2907 Temperature plots can be found in http://www.hep.lu.se/eudet/pictures/fectest/beam201009/