Comsic trigger (run number 741). Pedestal subraction and zerosuppression is ON. PCA16 is set to lowest gain (=6mV/fC) and longest shaping. The size of the pads are 1x6mm. The cosmic muon is perpendicalur to the two rows (1mm face). TPC is connected to the two rows of pads 2x64 to one FEC. Time is always given in sample number. 1) pedestals and rms for the ALTRO channels, high voltage is off the rms value is < 1 ADC count, one ADC count is 1 mV => 1/6 fC => 1000 electrons. 2) Charge distribution with a landau fit. the charge in one event is the sum of all ADC values. 3) Hit pattern as function of pad number in X (numbered 0-63, both pad rows summed) 4) Time distribution of the front of all cluster for each ALTRO channel X=time, Y=ALTRO channel. 5) Event display of ene event X = time, Y = ALTRO channel, Z = pulse height