20240311 ======== Took 11 runs with cosmic triggers. Run 0 events Run1-4,7-12 10 events Two runs: run 5 (1000 evts) and 6 (10000 evts) were with free running software trigger (not looked at yet). Temperature rise from ca 30 to 60 degrees during the 10 triggers. Plots: allevents.pdf all events from all runs. Only time slices with a (ADC value - pedestal) above a threshold of 10 are showns Pedestals are calculated using the last 20 time samples (989-1008) of the time sweep. event 0: all events in a run overlayed else individual events. 3 plots per 'event': xy plot (colour = number of time slices above threshold). time projection (box size = pulse height) 3D view (box size = pulse height) Pedestals are temperature sensitive. Pedestals were calculated event by event as described above. Pedestal plots: pedevents.pdf plot 1: all events and channels. If one zoom the plot one can see how the pedestal changes by ca 3 ADC counts. (rise by increasing temperature (?)). plot 2: 'rms' of pedestals (i.e. adc(time989 to 1008)-pedestal)) Individual events: mcm0-all-evt1-0-chamber.pdf mcm1-all-evt1-0-chamber.pdf mcm0-all-evt2-0-chamber.pdf mcm1-all-evt2-0-chamber.pdf mcm0-all-evt2-12-chamber.pdf mcm1-all-evt2-12-chamber.pdf At the place of the signals do all channels have a tendancy for a dip. To be looked at in detail. Seen in ALICE as well. Anders can explain. Some channels have 'bad' pedestals. mcm1: chip 3 (2 channels) and 6 (2 channels).